DS1921G
Thermochron iButton Device
Status Register Map
ADDRESS
0214h
BIT 7
TCB
BIT 6
MEMCLR
BIT 5
MIP
BIT 4
SIP
BIT 3
0
BIT 2
TLF
BIT 1
THF
BIT 0
TAF
Status Register
The Status register holds device status information
and alarm flags. The register is located at address
0214h. Writing to this register does not necessarily
end a mission.
The functional assignments of the individual bits are
explained below. The bits MIP, TLF, THF, and TAF can
only be written to 0. All other bits are read-only. Bit 3
has no function.
Bit 7: Temperature Core Busy ( TCB ). If this bit reads
0, the DS1921G is currently performing a temperature
conversion. This temperature conversion is either self-
initiated because of a mission being in progress or initi-
ated by a command when a mission is not in progress.
The TCB bit goes low just before a conversion starts
and returns to high just after the result is latched into
the Read-Out register at address 0211h.
Bit 6: Memory Cleared (MEMCLR). If this bit reads 1,
the memory pages 17 and higher (alarm timestamps/
durations, temperature histogram, excluding data-log
memory), as well as the Mission Timestamp, Mission
Samples Counter, Mission Start Delay, and Sample
Rate have been cleared to 0 from executing a Clear
Memory function command. The MEMCLR bit returns to
0 as soon as writing a nonzero value to the Sample
Rate register starts a new mission, provided that the EM
bit is also 0. The memory has to be cleared in order
for a mission to start.
Bit 5: Mission in Progress (MIP). If this bit reads 1, the
DS1921G has been set up for a mission and this mis-
sion is still in progress. A mission is started if the EM bit
of the Control register (address 20Eh) is 0 and a nonze-
ro value is written to the Sample Rate register, address
20Dh. The MIP bit returns from logic 1 to logic 0 when a
mission is ended. A mission ends with the first write
attempt (Copy Scratchpad command) to any register in
Maxim Integrated
the address range of 200h to 213h. Alternatively, a mis-
sion can be ended by directly writing to the Status reg-
ister and setting the MIP bit to 0. The MIP bit cannot be
set to 1 by writing to the Status register.
BIT 4: Sample in Progress (SIP). If this bit reads 1, the
DS1921G is currently performing a temperature conver-
sion as part of a mission in progress. The mission sam-
ples occur on the seconds rollover from 59 to 00. The
SIP bit changes from 0 to 1 approximately 250ms
before the actual temperature conversion begins allow-
ing the circuitry of the chip to wake up. A temperature
conversion including a wake-up phase takes maximum
875ms. During this time, read accesses to the memory
pages 17 and higher are permissible but can reveal
invalid data.
Bit 2: Temperature Low Flag (TLF). Logic 1 in the
temperature low flag bit indicates that a temperature
measurement during a mission revealed a temperature
equal to or lower than the value in the Temperature Low
Threshold register. The temperature low flag can be
cleared at any time by writing this bit to 0. This flag
must be cleared before starting a new mission.
Bit 1: Temperature High Flag (THF). Logic 1 in the
temperature high flag bit indicates that a temperature
measurement during a mission revealed a temperature
equal to or higher than the value in the Temperature
High Threshold register. The temperature high flag can
be cleared at any time by writing this bit to 0. This flag
must be cleared before starting a new mission.
Bit 0: Timer Alarm Flag (TAF). If this bit reads 1, a
RTC alarm has occurred (see the Timekeeping section
for details). The timer alarm flag can be cleared at any
time by writing this bit to logic 0. Since the timer alarm
cannot be disabled, the TAF flag usually reads 1 during
a mission. This flag should be cleared before starting a
new mission.
15
相关PDF资料
DS1921H-F5# IBUTTON THERMOCHRON F5
DS1921K# KIT IBUTTON THERMOCHRON
DS1922E-F5# IBUTTON TEMP LOGGER 4KBit F5
DS1922L-F5# IBUTTON TEMP LOGGER
DS1923-F5# IBUTTON TEMP/HUMIDITY LOGGER F5
DS1961S-F3# IBUTTON EEPROM 1KBit F3
DS1963S-F5+ IBUTTON MONETARY SHA-1
DS1971-F3+ IBUTTON EEPROM 256KBIT F3
相关代理商/技术参数
DS1921G-F5#W 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921G-F5/A0C 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921G-F5/A12 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921G-F5/A12-W 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921G-F5/A14 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921G-F5/A15 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921G-F5/A17 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921G-F5/A1B 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated